Address area: Rosecrest master-planned community, western Riverton, UT 84065 (specific address confidential per homeowner request). Project completion: October 2025. Scope: Two-stage variable-speed condensing gas furnace installation replacing 2005 single-stage 80% AFUE original construction furnace. Home: 2,860 sq ft two-story with unfinished basement built 2005 in Rosecrest master-planned community, existing matched 2005 Carrier 13 SEER AC continuing in service. This case study documents the pre-installation evaluation identifying multi-stage upgrade opportunity, homeowner priorities favoring quiet operation and humidity control improvements, Carrier Performance series two-stage 96% AFUE furnace selection, coordination with existing matched AC, and homeowner outcome from the upgrade.
Rosecrest is a master-planned Riverton community developed primarily 1999–2015 covering western Riverton hillside areas. Housing stock features tract single-family residential typically 2,200–3,500 sq ft with typical 2000s master-planned envelope specifications (R-30 attic, R-13 walls, standard double-pane windows). Original HVAC installations from the era typically featured 80% AFUE atmospheric furnaces paired with 12–13 SEER AC on standard forced-air distribution.
2005 original construction HVAC:
Pre-installation evaluation identified upgrade opportunity: (1) 20 year-old furnace approaching end-of-service-life, homeowner ready for proactive replacement before failure scenario; (2) 80% AFUE atmospheric technology 15% less efficient than modern 95%+ AFUE condensing options; (3) single-stage cycling operation producing temperature swings and inconsistent humidity, homeowner particularly noting summer humidity control issues; (4) 100,000 BTU/hr input capacity oversized relative to actual 2,860 sq ft Manual J load, contributing to short-cycling and comfort issues; and (5) matched 2005 AC continuing in acceptable condition with likely 5–10 year remaining service life, warranting furnace-only replacement scope with future AC replacement scheduled separately.
Homeowner priorities established during pre-installation consultation: quieter operation (primary bedroom directly above mechanical room, existing single-stage furnace producing noticeable startup and cycling noise), improved humidity control (summer humidity levels 55–65% RH causing discomfort even at reasonable temperature setpoints), better temperature consistency (existing single-stage cycling producing 3–4°F swings around setpoint), energy efficiency improvement (Dominion Energy gas billing motivation), and reasonable equipment tier decision balancing feature benefits with cost.
Equipment tier decision between two-stage 96% AFUE Carrier Performance series and premium variable-speed modulating 98% AFUE Carrier Infinity series:
Two-stage Performance series selected based on: (1) 65% low-fire operation provides much of the comfort benefit of full modulation (temperature swing reduction, longer run times for better humidity control, quieter operation than single-stage) at meaningfully lower cost, (2) ECM variable-speed blower provides continuous fan operation option and modulated blower speed matching stage operation, (3) 96% AFUE altitude-corrected efficiency essentially equivalent to Infinity 98% AFUE altitude-corrected efficiency in Bluffdale/Riverton climate, (4) standard non-communicating thermostat compatibility allows homeowner flexibility in thermostat selection (Nest, Ecobee, or Carrier smart thermostats), and (5) cost savings of approximately $2,400 versus premium tier applied to potential future matched AC replacement.
Manual J load calculation for 2,860 sq ft home:
Carrier Performance series 59TN6 two-stage 96% AFUE condensing gas furnace:
Ecobee SmartThermostat Premium selected as replacement thermostat: standard 24V non-communicating installation compatible with Carrier Performance series two-stage furnace, dual-stage heating control (initiates low-fire, escalates to high-fire per programmed timeout), Wi-Fi connectivity with Ecobee app for remote access and scheduling, room sensor integration for whole-home temperature averaging (Ecobee sensors placed in primary bedroom and living room), and Alexa/Google Home integration for voice control.
Total installation timeline: 2 days of active work. Day 1: existing furnace removal after gas shutoff and electrical disconnection, evaporator coil careful preservation (continues in service with existing matched AC), and new Carrier Performance 59TN6 furnace setting in mechanical room. Day 2: PVC direct-vent installation with side-wall penetration and concentric termination, chimney abandonment coordination, gas line connection with new shutoff valve and union, electrical connections to blower motor and controls, condensate line routing to floor drain, Ecobee thermostat installation and configuration with room sensors, and commissioning verification.
Existing masonry chimney abandoned for boiler-only venting: metal B-vent liner removed from chimney interior, chimney cap installed at chimney top preventing water infiltration, chimney flue closed at top and bottom preventing air infiltration, and existing chimney structure remains for aesthetic reasons but no longer functional for combustion venting. Gas water heater retained on separate metal B-vent through side wall (installed in 2019 water heater replacement scenario, not affected by furnace conversion).
Combustion analyzer verification with Bacharach InsightPlus at both low-fire and high-fire operation:
Airflow and static pressure verification:
Ecobee thermostat configuration verified: two-stage heating control with 15-minute timeout for low-fire before escalation to high-fire, humidity control mode enabled with Carrier furnace ECM blower coordination, room sensor averaging enabled with primary bedroom weighted higher during sleep hours, and scheduling programmed for household patterns.
Winter 2025–2026 heating season performance verification:
Anticipated summer 2026 humidity control improvement:
Anticipated long-term outcome: approximately 15% reduction in Dominion Energy gas consumption reflecting 80% AFUE atmospheric vs 96% AFUE condensing efficiency improvement plus modulation benefits over cycling operation of single-stage prior equipment.
Post-installation incentive coordination: federal IRA 25C tax credit documentation ($600 for qualifying 96% AFUE condensing equipment), and Dominion Energy ThermWise condensing furnace rebate application ($400).
Multi-stage furnace installation with two-stage and variable-speed modulating Carrier equipment tier selection consultation, Manual J load calculation with altitude-adjusted design conditions and right-sizing analysis, Carrier Performance series 59TN6 two-stage 96% AFUE condensing gas furnace installation with ECM variable-speed blower, matched AC compatibility verification and coordinated CFM matching for continuing service on existing equipment, PVC direct-vent installation with side-wall concentric termination and chimney abandonment coordination, Ecobee SmartThermostat Premium installation with two-stage control programming and room sensor integration, combustion analyzer verification at both low-fire and high-fire operation with efficiency measurement, humidity control coordination with cooling season dehumidification mode, federal IRA 25C ($600) and Dominion Energy ThermWise ($400) incentive coordination, and 24/7 emergency response all route through our office at 14659 S 855 W in Bluffdale serving the greater Salt Lake Valley including Riverton Rosecrest.